Medium frequency furnace special water cooling cable selection method

Time: 2019-06-15

Medium frequency furnace special water cooling cable selection method

image.png Water cooled cable

The joints of the water-cooled cable can be disassembled in a detachable structure. The inside is connected to the copper strand by cold pressing. This way the connection is firm and the contact resistance is small. The outer casing of the water-cooled cable is a rubber tube. This hose is not easy to burn and has good strength. It can withstand 0.45Mpa water pressure without leaking or breaking.The rubber tube will age after long-term use and will be replaced at this time. This detachable structure does not need to damage the internal copper strands. It is only necessary to disassemble the bolts on the joints to easily replace the outside. The inside of the joints is sealed with a tapered cone and is electrically conductive. When the joint bolt is tightened, it naturally acts as both conductive and sealed.

Since the outer rubber tube of the water-cooled cable rubs against the ground every time the furnace is tilted, it will be damaged for a long time. In this regard , our company is equipped with a water-cooled cable bracket on each set of equipment. When the furnace is tilted, the cable does not directly contact the ground, thus extending the service life of the water-cooled cable.



Recommended Reading: Medium Frequency Furnace